This dial indicator has a faster response than digital probe. This is used to level bed to gantry.
Step 1) Auto Home
Step 2) Adjust the bed to desired distance from nozzle using a piece of paper.
Step 3) Move Hotend 70mm or to center on the X axis.
Step 4) Place Dial Indicator with holder on the gantry to the left corner..
Step 5) Note the reading on the dial indictor.
THIS IS YOUR NEW DEFAULT (exp 1.45mm)
Step 6) Place Dial Indicator on the right corner and make adjustments to your default (exp. 1.45mm).
Step 7) Adjust back left and right corners. Repeat until all corners are within an acceptable tolerance of your default.