Bed Leveling Probe (BLTouch) Mount For BiQu H2v2 3D Printer Model

Author: @
License: CC BY-SA
File formats: f3d,stl
Download type: zip
Size:2.7MB

The file 'Bed Leveling Probe (BLTouch) Mount For BiQu H2v2 3D Printer Model' is (f3d,stl) file type, size is 2.7MB.

Summary

Benefits over other mounts

Easy to install

Ever had those screws or nuts constantly falling down while trying to mount your BLTouch with a mount designed for someone who seems to have 3 hands (one to hold the BLTouch, one for the nut, and another for the screwdriver)? This mount can actually be easily installed by one of the more common 2-handed humans.

Printed spacers

Ever installed a nozzle of a different length and now you need to add washers, but you already needed all of your 3 hands to install it, and now all your washers are falling down causing you to wish you had 4 hands that don't collide with each other? This mount does not need washers!
Switching the spacer takes less than 2 minutes!

Required parts

  • 2 x M3 metal-threaded inserts. Alternatively: 2 x M3 nut. Using threaded inserts is recommend!
  • 2 x M3 screws of desired length (20mm recommended for the 7mm spacer). Used to mount the probe.
  • 2 x M3 screw 8 mm. Used to mount Core.stl to the extruder.

You need Core.stl and Fixture.stl. The size of the spacer depends on your nozzle. With the regular V6 nozzle i use the 7mm spacer.

One may need to scale the height (default: 5mm tall) of Fixture.stl if you use longer than 6mm inserts or you use non textured inserts.
If you use Fixture(Nut).stl you may need to glue in the nuts, to prevent them from falling out.

Print settings

Designed to prints without support!
I used 3 walls, and infill around 25%.

Compatibility

This was made for the Ender 5, but it should work with every printer that has 3mm free space to the front and 22mm free space to the right. If you can confirm that this works with another printer please comment.
I used the BiQu H2 Ender 5 Plus BlowThrough mount but it should work with every mount that mounts the BiQu H2v2 flush using only the 2 screw-holes at the back.

Based on the schematics it should also fit the H2V2S lite. I did not test this. If you can confirm this please add a comment.

Offset Settings

My settings are: M851 X55.00 Y-5.00 Z-2.55
Note that your Z distance may differ.

License

CC-BY-SA 4.0

BLTouch_mount_H2.f3d 1.9MB
Core.stl 98.2KB
Fixture.stl 98.1KB
FixtureNut.stl 114.3KB
Spacer_10mm.stl 181.3KB
Spacer_11mm.stl 155.2KB
Spacer_12mm.stl 172.3KB
Spacer_13mm.stl 207.3KB
Spacer_14mm.stl 173.7KB
Spacer_15mm.stl 196.6KB
Spacer_16mm.stl 210.0KB
Spacer_17mm.stl 190.3KB
Spacer_18mm.stl 225.5KB
Spacer_19mm.stl 218.1KB
Spacer_1mm.stl 103.0KB
Spacer_20mm.stl 234.1KB
Spacer_2mm.stl 133.5KB
Spacer_3mm.stl 146.4KB
Spacer_4mm.stl 112.8KB
Spacer_5mm.stl 134.8KB
Spacer_6mm.stl 172.3KB
Spacer_7mm.stl 138.0KB
Spacer_8mm.stl 178.8KB
Spacer_9mm.stl 183.3KB